Skip to main content
New products

Panasonic Aquarea EcoFlex: heating, cooling and hot water from one outdoor unit

By Kévin Hecker Panasonic Aquarea EcoFlex range

One outdoor unit to heat, cool and make hot water, reusing the heat removed by the air conditioning in summer. We explain how the Aquarea EcoFlex works, which homes it suits, and when we would advise something else.

Customers across the Lille area increasingly ask us the same thing: “I want to replace my heating, but I’d also like to stay cool in summer. Do I need two systems?” Until now the answer was often yes: a heat pump for heating and hot water, plus a separate air conditioner, with two outdoor units on the wall.

With Aquarea EcoFlex, Panasonic brings all of this together around a single outdoor unit. We saw the range up close on a Panasonic stand (our photo below). Here is what you need to know, with figures from the manufacturer’s data sheets, and our view as an RGE-certified installer (the French “Recognised Environmental Guarantor” label) on when it makes sense… and when it doesn’t.

What is the Aquarea EcoFlex?

It is a heat pump that combines two families usually installed separately:

  • air-to-air: heat taken from the outdoor air is blown straight into rooms by indoor units (wall-mounted or hidden in a ceiling). This is how reversible air conditioning works, heating in winter and cooling in summer;
  • air-to-water: heat taken from outside is passed to water, which then flows through radiators or underfloor heating and also produces DHW (domestic hot water, for showers and taps).

Panasonic specifies up to 3 air-to-air indoor units (Etherea wall units and ducted units) for heating and cooling, combined with hot-water production and, as an option, water-based heating for radiators or underfloor heating.

Its output is not fixed: in cooling, the outdoor unit data sheet gives 1.6 to 10.2 kW. That is the Inverter principle: the compressor adjusts its speed to demand instead of switching on and off, which means fewer jolts, less noise and lower consumption. The refrigerant carrying the heat is R32, common on current heat pumps.

Panasonic unveiled the new generation (dark grey outdoor unit, redesigned air-to-water indoor unit) on 21 November 2025, and the version with a simple hot-water cylinder is announced from autumn 2026.

Panasonic Aquarea EcoFlex stand: black outdoor unit, EcoFlex hot-water cylinder, black and white Etherea wall units and the EcoFlex ducted unit label
The Aquarea EcoFlex range on a Panasonic stand: outdoor unit, hot-water cylinder, Etherea wall units and ducted unit. Photo: HFE.

What is different from a standard air-to-water heat pump or air conditioner

  1. Hot water made from the cooling heat. When an air conditioner cools your living room, it dumps the heat outside. In cooling mode, the EcoFlex recovers that heat to warm the hot-water cylinder. Panasonic quotes a COP (coefficient of performance: heat produced per 1 kWh of electricity) of 5.11 in this mode, for water at 55 °C. Savings are shown in the Panasonic Comfort Cloud app.
  2. Two ways of heating at once. With the air-to-water indoor unit, radiators or underfloor heating provide steady background warmth while the air-to-air units give a quick boost.
  3. No interruption during defrost. In cold weather every heat pump must defrost its outdoor unit. On the EcoFlex, stored heat from the cylinder is used, and air-to-air heating keeps running.

With one outdoor unit instead of two, there is also less equipment on the wall and only one outdoor unit to service. Compare with our heat pump and air conditioning pages.

The components of the range

  • K-series outdoor unit (CU-4WZ90CBE5): Panasonic data sheet. Single-phase (230 V), 9 kW cooling with 2 or 3 indoor units, 7.1 kW with a single ducted unit. 999 × 940 × 340 mm, heating down to −25 °C outside.
  • K-series air-to-water indoor unit (WH-ADF0309K3E5M): Panasonic data sheet. The size of a tall fridge (1,882 × 599 × 602 mm) with a vacuum-insulated (U-Vacua) 185-litre hot-water tank and 8 kW for radiators or underfloor heating. A WH-ADF0309K3E5ANM version with an electronic anode is designed for hard water, common around Lille.
  • Etherea wall units: Panasonic data sheet. 2.5 to 7.1 kW, in matt white, silver or graphite grey, with Wi-Fi and nanoe™ X air purification. The smallest model goes down to 19 dB(A) in heating at very low speed.
  • EcoFlex ducted unit (S-71WF3E): Panasonic data sheet. A ducted unit is hidden in a ceiling void or loft and blows air through discreet grilles into several rooms. This one is 7.1 kW and only 250 mm high, with a built-in condensate pump.
  • Low static pressure ducted unit: Panasonic data sheet. 2.0 to 6.0 kW, 200 mm high, for shallow ceilings.

Everything is controlled from the Comfort Cloud app. The ducted units can also take an optional Modbus, KNX or BACnet interface: standard protocols that connect the system to home automation or a building management system.

The full range is on Panasonic’s Aquarea EcoFlex page.

Key figures at a glance

SCOP (seasonal coefficient of performance) is the average kWh of heat produced over a heating season per 1 kWh of electricity. The “35 °C” figure applies to underfloor heating, the “55 °C” figure to radiators.

ComponentFeaturePanasonic figure
Outdoor unit CU-4WZ90CBE5Cooling (2 to 3 indoor units)9.0 kW, SEER 7.00 (A++)
Outdoor unit CU-4WZ90CBE5Air-to-air heating (2 to 3 units)9.5 kW, SCOP 4.60 (A++)
Outdoor unit CU-4WZ90CBE5Sound pressure at 1 m (heating)55 dB(A)
Outdoor unit CU-4WZ90CBE5RefrigerantR32
Outdoor unit CU-4WZ90CBE5Heating operationdown to −25 °C outside
Air-to-water indoor unitHeating (7 °C outside, water at 35 °C)8.0 kW, COP 4.21
Air-to-water indoor unitSCOP average climate, 35 °C / 55 °C4.00 / 3.20 (A++ / A++)
Air-to-water indoor unitBuilt-in hot-water tank185 L, profile L, class A
Air-to-water indoor unitFootprint599 × 602 mm
Air-to-water indoor unitSound pressure28 dB(A)
Etherea wall unitsOutput range2.5 to 7.1 kW
Ducted unit S-71WF3EOutput / height7.1 kW / 250 mm

Figures taken on 31 October 2026 from the Panasonic data sheets linked above. Real-world performance depends on the home, emitters and settings.

When the EcoFlex is a good choice

  • You want heating, hot water AND summer cooling. That is the main use case: one system does all three, and hot water benefits from recovered heat.
  • Renovation with water radiators or underfloor heating. The air-to-water indoor unit uses your existing system, and wall or ducted units are added where you want cooling. Underfloor heating gives the best efficiency (SCOP 4.00 at 35 °C).
  • Houses with upstairs rooms that overheat in summer. A ducted unit in the loft or wall units upstairs solve it, while the ground floor stays on water heating.
  • Compact homes with no room for a boiler room. In the cylinder-only configuration expected from autumn 2026, heating and cooling go through air-to-air units and hot water through the cylinder, which Panasonic presents as a compact solution with fewer components. The air-to-water unit itself fits a standard kitchen-appliance space.
  • Low ceilings. The low static pressure ducted unit is only 200 mm high.
  • Hard water. The electronic-anode version better protects the tank.

Does your home match one of these cases? We visit, calculate your needs and tell you whether EcoFlex is the right fit: ask for a free quote.

When it is not the right choice

  • You don’t need cooling. A standard air-to-water heat pump is simpler and often cheaper.
  • Large, energy-hungry houses. The air-to-water unit delivers 8 kW and the outdoor unit is single-phase. We always run a heat-loss calculation first.
  • Old radiators that need very hot water. At 55 °C the SCOP drops to 3.20. Insulation or radiator upgrades may come first.
  • Apartment buildings with central heating. EcoFlex is a residential range. For co-ownership buildings we use high-output heat pumps in cascade, as in the Lille building covered by La Voix du Nord.
  • Replacing only a water heater. A heat-pump water heater is enough.

Possible grants

  • MaPrimeRénov’ and energy savings certificates (CEE) may cover the air-to-water heating part when it replaces old heating and is installed by an RGE company. The air-to-air part is not eligible for MaPrimeRénov’.
  • Reduced VAT on energy renovation work in homes over two years old: see our article on 5.5% VAT and reversible air conditioning.
  • The zero-interest eco-loan (éco-PTZ) to finance the remainder.

We check eligibility case by case and show it on the quote. More on our grants and financing page.

Our view as installers

EcoFlex meets a real need: more and more families want one system all year round. Recovering heat for hot water is simple and effective, and heating that keeps running during defrost makes a real difference in the cold, damp weather we often get in the North.

As with any heat pump, results depend on sizing and installation. We are a Panasonic partner and install across the Lille area, for heating, air conditioning or both.

Unsure between EcoFlex, a standard heat pump and air conditioning? Ask for a free quote: we visit your home and recommend what suits it, even if it isn’t the most expensive option.

Free quote

Planning heating with summer cooling?

Home visit, needs calculation and free quote across the Lille area.

Frequently asked questions

Does the Aquarea EcoFlex also provide air conditioning?

Yes. Its air-to-air indoor units (Etherea wall units or ducted units, up to 3) cool in summer, and the heat removed from the house is used to warm the hot-water tank.

Can I keep my radiators or underfloor heating?

Yes, with the air-to-water indoor unit. It supplies water radiators or underfloor heating and makes hot water in its 185-litre tank.

Does it work in very cold weather?

Panasonic specifies heating operation down to −25 °C outside with the CU-4WZ90CBE5 outdoor unit. During defrost, air-to-air heating continues using stored heat.

Which refrigerant does it use?

The Panasonic data sheets for the K-series outdoor unit state R32.

Is it noisy?

Panasonic states 28 dB(A) for the air-to-water indoor unit and 55 dB(A) at 1 metre for the outdoor unit in heating. We always study where to place the outdoor unit.

When is it available?

Panasonic unveiled the new generation in November 2025. The cylinder-only configuration is announced from autumn 2026. Contact us for current lead times.

Which grants apply?

The air-to-water heating part may qualify for MaPrimeRénov’ and CEE under conditions, reduced VAT may apply to energy renovation work, and the éco-PTZ can finance the rest. The air-to-air part is not eligible for MaPrimeRénov’.